Please ensure Javascript is enabled for purposes of website accessibility Skip to content

Your Cart (0)

View cart

Your cart is empty

Continue shopping

Fiber Optic Macintosh Laryngoscope Set with Case

MFR#: 69696
TIGER#: TM8873
Original price List Price: $1,372.00
You Save: $368.38 -27%
Original price $1,372.00 - Original price $1,372.00
Original price List Price: $1,372.00
Current price $1,003.62
$1,003.62 - $1,003.62
Current price $1,003.62
Add to cart for Lower Price
As low as $/mo.
Apply at Cart
Fiber Optic Macintosh Laryngoscope Set with Case
Fiber Optic Macintosh Laryngoscope Set with Case - $1,003.62
$1,003.62
*Must Purchase 1 for Fiber Optic Macintosh Laryngoscope Set with Case

The cart will thereforce automatically set Qty to 1 when you order this product

Ships Out Within: 2 - 4 Business Days Shipping Date By: 4/24/2024
Documents

Fiber Optic Macintosh Laryngoscope Set with Case

The Fiber Optic MacIntosh set feature powerful halogen HPX illumination.

Light output is nearly three times more than the standard (lamp) set. The Macintosh set includes bothof Welch Allyn’s "AA" and "C" cell battery lightweight handles and lightweight blades for maximum maneuverability.

Blades are manufactured from one piece stainless steel, and the handles of chrome-plated brass, to assure a lifetime of performance. Handles feature a knurled finish for a comfortable and secure grip.

The Macintosh blades are the most popular of all curved-blade styles. The blade design incorporates a gentle, continuous curve from the tip to the proximal end. The curve is compressed into the vallecula and the blade lifted, indirectly raising the epiglottis.

The blade height assists in intubating patients with limited oral access.

Included is Fiber Optic Macintosh Laryngoscope Set Model:

69696- Fiber Optic MacIntosh Set Includes

  • Fiber Optic Macintosh Blades # 1, 2, 3, 4
  • 2.5 V Medium Handle uses C Cell Batteries
  • 2.5 V Penlight Handle uses AA Batteries
  • 05691-U Case

Robust Design

Welch Allyn’s laryngoscope design uses a single piece of 304-series stainless steel as its load-bearing member.This one-piece construction of the Welch Allyn blade is more robust than the typical competitive product.Furthermore, its one-piece blade construction eliminates the potentially weaker soldered or brazed joint.

Design Features

Welch Allyn’s innovative design incorporates an easy-to-remove light pipe that eliminates the difficult-to clean areas of most competitive laryngoscopes.

Removable Light Pipe

Another feature designed to help improve the cleaning of a Welch Allyn blade is its surface finish. Typical laryngoscope finishes have a surface roughness of 32μ in. The surface finish used on all Welch Allyn blades has a roughness of just 8μ in. This creates a surface texture that is approximately four times smoother than competitive blades, resulting in an easier-to-clean, stain-resistant laryngoscope blade. What’s more, the surface finish is not a plating, and therefore does not alter the 304-series stainless steel construction of the blade itself.

Brighter by Design

The Welch Allyn Halogen HPX™ lamp is the latest technology in gas-filled lamps. The lamp is more than 30% brighter and whiter than standard halogen lamps.

More Value by Design

There are primarily two causes of reduced light transmission in fiber optic laryngoscopes: fiber optic breakage and epoxy blockage. Light degradation caused by fiber optic breakage will occur in varying degrees in any laryngoscope that is subjected to severe changes in temperature.

  • When a fiber optic laryngoscope is steam-sterilized, the heat involved causes the epoxy (used to hold the fibers in place within the fiber optic bundle) to expand and extrude past the end of the light pipe.
  • The epoxy cools following the autoclave process and hardens over the optics, blocking light emissions from those fibers. As more and more fibers are blocked, less and less light is emitted and the accuracy of the intubation process may be jeopardized.

FREE Polishing Service

Welch Allyn’s state-of-the-art blade design allows for the removable fiber optic light pipe to be repolished throughout the life of the blade. When the optics are repolished, occluding epoxy is removed from the input and output points of the fiber optic pipe. This restores the light transmission to its optimum level, thus increasing the overall life of the blade. A Welch Allyn light pipe can be repolished three times over its lifetime—and can then be replaced at a fraction of the cost of a complete blade.

Welch Allyn will provide this repolishing service free of cost whenever it is needed over the life of the laryngoscope blades.

Upgradable and Repairable by Design

The removable fiber optic design truly makes Welch Allyn blades the smart choice for you. That’s because this unique design makes our blades the most affordable way to upgrade from standard to fiber optic lighting—while still offering the benefits of one-piece blade construction.

To upgrade to fiber optics, simply replace your current, standard lamp light pipe with the fiber optic pipe.

Fiber Optic Light Pipes

Welch Allyn fiber optic light pipes for laryngoscopes are guaranteed for five years against complete loss of performance. Therefore, during the first five years, Welch Allyn will polish or replace the fiber optic light pipe, free of charge, if performance is reduced due to repeated sterilization by steam autoclave.

Welch Allyn Warranty

Welch Allyn laryngoscope blades and handles are guaranteed against all manufacturing defects for the life of the instrument. Welch Allyn will repair or replace, free of charge, any parts of its own manufacture proven to be defective through causes other than misuse, neglect, damage in shipment or normal wear. Every Welch Allyn laryngoscope blade comes with a lifetime warranty against manufacturing defects.

Order now by clicking "Add to Cart!" in the drop down box above

Made in the USA

Warning WARNING: This product can expose you to chemicals known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.

  • A unique design that’s stronger, safer, upgradeable
  • Single-piece stainless steel construction
  • Removable light pipe and smooth surface design
  • Blades are upgradeable and repairable at a fraction of the cost of replacement blades
  • Lightweight laryngoscope handles with knurled finish
  • A unique design that’s stronger, safer, upgradeable and lower cost over the life of the instrument.
  • Single-piece stainless steel construction ensures blade integrity.
  • Removable light pipe and smooth surface design.
  • Free fiber-optic repolishing service extends product life.
  • Blades are upgradeable and repairable at a fraction of the cost of replacement blades.
  • Lightweight laryngoscope handles with knurled finish for secure and comfortable grip.

What’s in the Box

  • 60813- 2.5 V Medium Laryngoscope Handle
  • 60814 2.5 V Penlight Laryngoscope Handle
  • 69696- Fiber Optic MacIntosh Blades #1-#4
  • Carrying case
  • Lifetime Limited Warranty

ITEMS WITH A LEAD TIME LONGER THAN 48 HOURS CANNOT BE RETURNED / CANCELLED. These are specially ordered, and we cannot accept returns or cancellations on such products for any reason. We take the responsibility to make sure your product arrives in brand new working condition. Should your item arrive damaged, we will replace the product at no cost to you.

ITEMS WHICH SHIP OUT IN 24-48 HOURS. These are covered by our standard 30 day return policy from date of shipment. Return shipping charges are the responsibility of the customer. The product must be in new condition and in its original packaging.

For complete details of our return policy and process, please refer to our general return policy page.

ALLOCATED PRODUCTS BELOW ARE NON-CANCELLABLE, NON-RETURNABLE

  • PPE Apparel (Face Shields, Masks, Gloves, Gowns, Shoe Covers, Bouffant Caps, etc.) | COVID Tests | Alcohol / Alcohol prep pads | Batteries | Disinfecting solutions and wipes | Facial tissue | Hand sanitizers, soaps and dispensers | Hydrogen peroxide | | Spirometers | Thermometers | Saline / Solutions | Needles | Syringes
Blades
Blade Size
# 1, 2, 3, 4
Blade Type
Macintosh
Country of Origin
Product made in:
USA
Dimensions & Weight
Case Dimensions
11 x 10 x 11
Length
12"
Weight
10lbs.
Light Source
Type
Halogen HPX™
Voltage
2.5 V
Material(s)
Blade Material
Stainless Steel
Handle Material
Chrome Plated Brass
Power
Battery Type
AA and C Cell
Warranty
Lifetime Limited
  • Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)

    Compare products

    {"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

    Select first item to compare

    Select second item to compare

    Select third item to compare

    Compare