Please ensure Javascript is enabled for purposes of website accessibility Skip to content

Your Cart (0)

View cart

Your cart is empty

Continue shopping

Diagnostic Cardiology Suite Spirometry

MFR#: DCSS-NXX
TIGER#: TM107722
Original price $2,325.60 - Original price $2,325.60
Original price List Price: $2,325.60
$2,326.00
$2,326.00 - $2,326.00
Current price $2,326.00
Add to cart for Lower Price
As low as $/mo.
Apply at Cart
Diagnostic Cardiology Suite Spirometry
Diagnostic Cardiology Suite Spirometry - $2,326.00
$2,326.00
*Must Purchase 1 for Diagnostic Cardiology Suite Spirometry

The cart will thereforce automatically set Qty to 1 when you order this product

Does not include PC

Ships Out Within: 2 - 4 Business Days Shipping Date By: 5/14/2024

Spirometry provides a measure of lung function, specifically the amount and speed of air that can be inhaled and exhaled and generates pneumotachographs for diagnosis and assessment of conditions such as COPD, asthma, pulmonary fibrosis, cystic fibrosis, bronchitis, and shortness of breath. Welch Allyn's Diagnostic Cardiology Suite Spirometry, part of the Welch Allyn Diagnostic Cardiology Suite line of diagnostic tools, makes spirometry fast and simple by providing a common interface between spirometry and ECG modalities.

The Diagnostic Cardiology Suite turns a device into a two-in-one machine capable of doing spirometry and ECG tests, so you can maintain and connect one secure solution for simple exams. It allows for fast and easy viewing, comparison, storage, and printing of pulmonary function tests. It aids in the evaluation of pulmonary restriction or obstruction, slows progress in patients with a range of lung conditions, entices pediatric patients to cooperate, and helps with smoking cessation programs.

Measurement and display

The spirometer operates in several modes, customizable to each physician's and patient's individual needs. Patient data is entered directly into the PC for adjustment of readings accordingly and includes settings for asthmatics and smokers. The spirometer also automatically detects ambient temperature and pressure and compensates for it, preventing it from causing false readings.

One may select from three testing modes: FVC: Forced Vital Capacity; MVV: Maximum Voluntary Ventilation; and SVC: Slow Vital Capacity. Each effort may be further specified with pre or post-bronchodilator tags; when recording a post-bronchodilator effort, the details of the medication administered may be entered as well for highly accurate analysis.

Back to top

Once a patient has been entered into the database, it is simple to pull up his or her chart and previous tests for comparison, eliminating the need for paper charts, filing, and shredding. Test results and types are immediately viewable; the trending tool verifies and compares quality and variability of the current and previous tests. A snapshot of test results shows immediately, and customizable parameters make testing as accurate and easy to interpret as possible.

Back to top

The software allows the user to choose from multiple predicted norms and report formats. It displays real time curves as Flow/Volume, Volume/Time, Flow/Time, or Pre/Post, and may be customized to show all efforts and/or best efforts on the same graph for clear comparison. Automatic interpretation calculates lung age, follows ATS Interpretative Strategies and test reproducibility criteria. The clear, understandable test results are an excellent tool in smoking cessation programs, as they show the patient's lung capacity improvement over time.

Back to top

Software

The Diagnostic Cardiology Suite Spirometry Module turns any PC (see system requirements below) into a full-featured ECG with the added benefits of analytical software. The Diagnostic Cardiology Suite Software manages data from all of Welch Allyn's cardiopulmonary equipment, including ECGs and ABPMs, in the same way for storage of all patient information in the same record. This makes retrieval and analysis of the information quick and easy, allowing clinicians and their staff to interact more efficiently with patients. The software allows users to easily monitor trends and changes in patient history and retrieve previous records with the touch of a key; no more digging through paper files looking for the right information. Users may copy and paste spirographs directly into Microsoft® Word for additional saving, sharing, clarity, and viewing.

Back to top

Pediatric use

Spirometry tests can be difficult for children. They often do not want to cooperate and/or are not motivated to perform properly. The Diagnostic Cardiology Suite Spirometry module makes it easy and fun for children to take the test; an incentive graphic shows a child-friendly fireman attempting to extinguish a fire. Children are encouraged to "blow out the fire," which occurs when the patient's efforts reach 80% of predicted PEF and FVC values.

Back to top

EHR compatibility

The Diagnostic Cardiology Suite Spirometry software is EHR-friendly with a bi-directional interface; no printing, scanning, or complicated retrieval, as data is already in the chart. Fax urgent referrals in no time directly from the system; the database stores thousands of test records. This eliminates the need to sort through lengthy paper reports or interpret hard-to-read faxed copies of test results and makes information accessible virtually anywhere with access to a secure network.

Back to top

Printing

Once a measurement is complete, it may be printed via the PC and printer of the user's choice. This eliminates the priciness and fading common in thermal paper. The physician may preview and format the report according to his or her preference before printing.

Back to top

Accessories

The module includes a sensor, pressure tubing, reusable patient handle, nose clip, hygienic disposable flow transducers, and a spirometer sensor with a USB cable.

Customize your Diagnostic Cardiology Suite Spirometry Module

The spirometer may be ordered with or without a 3L calibration syringe. Select your preference from the drop-down menu in the upper right corner of this page, then click "add to cart" for hassle-free ordering at the lowest price!

Back to top

Minimum Computer Requirements (Recommended)

  • Processor: Intel® Core™ i3
  • RAM: Minimum 4 GB
  • Hard Drive: Minimum 250 GB (If client: minimum 160 GB)
  • Operating Systems: Microsoft® Windows® 7 Professional 32 bit and 64-bit and Microsoft® Windows® 10 Pro 64-bit operating systems
  • USB Ports: At least two USB 2.0 ports (acquisition module, external USB drive)
  • Installation: USB
  • Network: 100 Mbps connection or better required for use with server
  • Printing Device: HP M501dn Windows printer with HPUPD PCL 5 driver or equivalent
  • Waveform Display: Compatible with 1024 x 768, 1366 x 768, 1280 x 800, 1680 x 1050, 1920 x 1080, 1900 x 1200, and 2736 x 1824

Back to top

Made in the USA

Warning WARNING: This product can expose you to chemicals known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.

  • Turns any PC into a full-featured spirometer
  • Pre/post-bronchodilator FVC, SVC, and MVV testing
  • Reversibility analysis and automatic interpretation
  • Trending tool for test comparison; real-time reporting
  • EHR compatible
  • Pediatric incentive graphic motivates cooperation

Minimum Computer Requirements (Recommended)

  • Processor: Intel® Pentium® III (Pentium IV or higher)
  • Hard Drive: 2 GB (4 GB or more)
  • RAM: 256 MB (512 MB or higher)
  • Monitor Resolution: 1024 x 768 true color
  • Operating Systems: Windows® XP, Vista, and 7
  • CD-ROM: Required for installation
  • Printers: Color printer recommended. Compatible with inkjet and laser printers. Laser printers require a minimum of 2 MB of memory

What’s in the Box

Welch Allyn Diagnostic Cardiology Suite Spirometry, which includes:
  • Disposable flow transducers
  • Pressure tubing
  • Spirometer sensor with a USB cable
  • Reusable patient handle
  • Nose clip
  • 3-liter calibration syringe (optional)
  • User manual

ITEMS WITH A LEAD TIME LONGER THAN 48 HOURS CANNOT BE RETURNED / CANCELLED. These are specially ordered, and we cannot accept returns or cancellations on such products for any reason. We take the responsibility to make sure your product arrives in brand new working condition. Should your item arrive damaged, we will replace the product at no cost to you.

ITEMS WHICH SHIP OUT IN 24-48 HOURS. These are covered by our standard 30 day return policy from date of shipment. Return shipping charges are the responsibility of the customer. The product must be in new condition and in its original packaging.

For complete details of our return policy and process, please refer to our general return policy page.

ALLOCATED PRODUCTS BELOW ARE NON-CANCELLABLE, NON-RETURNABLE

  • PPE Apparel (Face Shields, Masks, Gloves, Gowns, Shoe Covers, Bouffant Caps, etc.) | COVID Tests | Alcohol / Alcohol prep pads | Batteries | Disinfecting solutions and wipes | Facial tissue | Hand sanitizers, soaps and dispensers | Hydrogen peroxide | | Spirometers | Thermometers | Saline / Solutions | Needles | Syringes
Compatibility
EHR Compatibility
Allscripts TouchWorks® EHR, Allscripts Pro, Aprima Medical Software, Medent, Doc-tor.com (Picasso), e-ClinicalWorks, e-MDs, EpicCare Ambulatory, Epiphany Healthcare, GE Healthcare, Greenway Medical Technologies, Henry Schein Medical Systems, iPatientCare, Jonoke Software Development, QHR Accuro, NextGen
Operating System Requirements
Microsoft® Windows® 7 Professional (32-bit* or 64-bit); Microsoft Windows 10 Professional (64-bit)
Connectivity
Export compatible with most electronic medical records programs; available in multiuser network
Part of the Welch Allyn® Diagonostic Cardiology Suite
Interpretation
Automatic interpretation can be enabled or disabled.
Lung Age calculation can be enabled or disabled.
1991 ATS Interpretation Standards.
Parameters
MVV, MV, VT, BF, DFRC
SVC, ERV, IRV, VT, IC, BF, MV, Tin, Tex, Tin/Tex
FVC, FIVC, FIV1, FIV1%, FEV0.5, FEV1, FEV2, FEV3, FEV5, FEV6, FEV0.5, FEV0.5%, FEV1%, FEV1/FVC, FEV2%, FEV3%, FEV5%, FEV6%, PEF, FEF25, FEF50, FEF75, FEF0.2-1.2, FEF25-75, FEF75-85, PIF, FIF50, FEF50/FIF50, FEV1/FEV6, FET, MEF25, MEF50, MEF75
Power
Power Supply Type
Via USB
Predictive Norms
Additional predictive norms may be added upon customer request.
Morris 1971, NHANES III 1999, Polgar 1971, Roca 1986, Schoenberg 1978, Solymar 1980, Viljanen 1981, Wang 1993, Zapletal 1969
Hedenström 1986, Hibbert 1989, Hsu 1979, Knudson 1976, Knudson 1983, Koillinen 1998, Kory 1961
Berglund 1963, Crapo 1981, Dockery 1983, ECCS/Quanjer 1993, Falaschetti 2004, Forche II 1988, GLI 2012, Langhammer 2001
Sensor
Sensor Type
Pneumotach
Standards & Certifications
SSD—Social Security Disability; ECCS—European Community for Coal & Steel
NIOSH—National Institute for Occupational Safety and Health; OSHA—Occupational Safety and Health Administration
ATS/ERS—American Thoracic Society/European Respiratory Society, Standardization of Spirometry, 2005 Update
Test Specifications
Accuracy
Compliant with ATS/ERS 2005 Guidelines and ISO 26782 Guidelines
Flow Range
14 L/sec
Report Type
Multiple report templates including FVC, SVC, MVV, measurement, and trend
Reproducibility
Compliant with ATS/ERS 2005 Guidelines and ISO 26782 Guidelines
Test Type
FVC, SVC, MVV, pre- and post-bronchiodilator
Volume Range
0-14 L
Warranty
Accessories
90 days
Main Device
1 year
  • Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)

    Compare products

    {"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

    Select first item to compare

    Select second item to compare

    Select third item to compare

    Compare